Ian Abbott authored
The pcl726 driver has an "interrupt" subdevice that supports Comedi
asynchronous commands, placing a value in the Comedi buffer for each
interrupt.  The subdevice uses Comedi's 16-bit sample format but the
interrupt handler is calling `comedi_buf_write_samples()` with the
address of a 32-bit integer `&s->state`.  On bigendian machines, this
will copy 2 bytes from the wrong end of the 32-bit integer.  This isn't
really a problem since `s->state` will always be 0 for this subdevice,
but clean it up by using a 16-bit variable initialized to 0 to pass the
value.

Signed-off-by: default avatarIan Abbott <abbotti@mev.co.uk>
Link: https://lore.kernel.org/r/20210223143055.257402-15-abbotti@mev.co.uk


Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>