Ian Abbott authored
The analog input subdevice supports Comedi asynchronous commands that
use Comedi's 16-bit sample format.  However, the call to
`comedi_buf_write_samples()` is passing the address of a 32-bit integer
variable.  On bigendian machines, this will copy 2 bytes from the wrong
end of the 32-bit value.  Fix it by changing the type of the variable
holding the sample value to `unsigned short`.

Fixes: d1d24cb6

 ("staging: comedi: das6402: read analog input samples in interrupt handler")
Cc: <stable@vger.kernel.org> # 3.19+
Signed-off-by: default avatarIan Abbott <abbotti@mev.co.uk>
Link: https://lore.kernel.org/r/20210223143055.257402-5-abbotti@mev.co.uk


Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>